Water Leak Repair Guide

Thermal Imaging

Thermal Imaging Surveys

Thermal imaging shows what surfaces hide: temperature differences caused by escaping water, missing insulation, air leaks and wet assemblies. It is fast, non-contact, and strongest when paired with moisture readings and acoustic confirmation.

Symptoms we're called for

  • Stains or soft drywall with no obvious source
  • Inconsistent room temperatures and unexplained cold zones
  • Moisture that returns after drying or painting
  • A ceiling or wall that feels cool or damp to the touch

Property types

  • Homes, condos and townhouses
  • Strata common property and parkades
  • Commercial and institutional buildings
  • Envelope, roof and below-grade assemblies

Methods used

  • Infrared scanning under controlled temperature conditions
  • Moisture metering to confirm thermal anomalies as wet, not just cool
  • Acoustic follow-up on plumbing where the anomaly aligns with a pipe route
  • Comparative scans before and after mitigation

Limitations, stated plainly

  • Thermal anomalies are clues, not proof: every finding is confirmed with a second method
  • Scan quality depends on temperature differential and surface conditions
  • Concealed cavities may need a small access point to verify

What you receive

  • Annotated thermal images with temperature references
  • Moisture readings taken at each anomaly
  • A written interpretation separating confirmed findings from areas to monitor
  • Next-step recommendations by trade

Next steps

  • Confirm the source with the recommended follow-up method
  • Give findings to the repair trade before opening finishes
  • Re-scan after repair to verify the anomaly has resolved